Each grab bar shall be 24 inches 610 mm long minimum and shall be installed 24 inches 610 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Handicap grab bar height requirements.
The toilet paper dispenser shall be mounted below the grab bar at a minimum height of 19 inches 485 mm.
A u shaped grab bar or three separate grab bars shall be provided.
The grab bar or bars shall be 33 36 inches 840 915 mm high.
Side wall grab bars should be at least 42 inches in length with one end 12 inches or less away from the wall behind the toilet and one end at least 54 inches away from that wall.
A 42 inches 1065 mm minimum length grab bar is required on the side wall spaced a maximum of 12 inches 305 mm from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height of 33 36 inches 840 915 mm.
The controls shall be placed in an area between 38 48 inches 965 1220 mm above the floor.
Controls shall be located on the back long wall 27 inches 685 mm from the side wall.