International residential code 2015 irc 2015 most popular sections section r403 footings section r304 minimum room areas section r905 requirements for roof coverings section r908 reroofing section r602 wood wall framing section r307 toilet bath and shower spaces section r301 design criteria section r404 foundation and retaining walls section.
Gutters in 2015 irc.
Concrete cmu foundations that contain habitable or usable space need drains 405 1 unless there is good natural drainage 405 1x.
Some of the relevant code language states that the truss design drawings shall be prepared by a registered professional and truss design drawings shall be provided to the building official and approved.
All code references are to the irc unless otherwise specified.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Irc sections r502 1 4 and r502 11 provide clear guidance about what is required when engineered i joists are used in a design.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Chapter 10 city amendment.
Install house siding over the step flashing ending at least one inch above the roof surface.
If metal the flashing should be made of galvanized steel at least 0 019 inches thick irc 2015.
International residential code 2015 irc 2015 part i administrative chapter 1 scope and administration part ii definitions chapter 2 definitions part iii building planning and construction chapter 3 building planning chapter 4 foundations.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Where the roof sheathing is less than 3 4 inch 19 mm thick the.
Fasteners for asphalt shingles shall be galvanized steel stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 3 mm shank with a minimum 3 8 inch diameter 10 mm head astm f 1667 of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 mm into the roof sheathing.
Sections 404 405 406 and 801 of the international residential code irc relate to foundations and below grade habitable space.
Where siding is provided on the vertical sidewall the vertical leg of the flashing shall be continuous.
Install shingles over the portion of step flashing on the roof.
International residential code 2015 irc 2015 part i administrative chapter 1 scope and administration part ii definitions.
Install roof felt prior to installing the step and kick out flashing.